We don't have any photos of this building yet. Why don't you be the first to send us one?
Latitude: 55.1647 / 55°9'53"N
Longitude: -4.1903 / 4°11'25"W
OS Eastings: 260566
OS Northings: 587790
OS Grid: NX605877
Mapcode National: GBR 4V.JMK7
Mapcode Global: WH4TQ.LGT0
Plus Code: 9C7Q5R75+VV
Entry Name: Kendoon Valve House
Listing Name: Galloway Hydroelectric Power Scheme, Kendoon Power Station and Valve-House
Listing Date: 11 February 2011
Category: B
Source: Historic Scotland
Source ID: 400606
Historic Scotland Designation Reference: LB51694
Building Class: Cultural
ID on this website: 200400606
Location: Dalry (Dumf & Galloway)
County: Dumfries and Galloway
Electoral Ward: Dee and Glenkens
Parish: Dalry (Dumf & Galloway)
Traditional County: Kirkcudbrightshire
Tagged with: Architectural structure
Sir Alexander Gibb consulting engineer; Merz and McLellan, electrical engineers; dated 1934. Symmetrical 10-bay, 2-storey rectangular-plan Classical Modern power station with lower terminal bays to left (S). Painted reinforced concrete. Full height pilasters with recessed parapet above. Slightly advanced door surround with large vehicular opening and steel shutter. Inscribed above: THE GALLOWAY WATER POWER SCHEME, KENDOON POWER STATION, 1934. Large full-height rectangular multi-pane windows; regular fenestration to lower block with pedestrian doors at ground floor.
Multi-pane glazing in metal frame windows. Flat platform roof behind parapet with integrated cast-iron rainwater goods.
INTERIOR: plain interior with large roller crane on steel girders supported by corniced concrete piers. Engineered steel roof trusses.
VALVE-HOUSE: 4-bay, single storey rectangular-plan painted concrete valve-house. Recessed deep base course and eaves course. Large multi-pane rectangular windows, bi-partite to centre.
Kendoon power station is a significant example of a hydroelectric power station and was an important part of phase II of the highly influential Galloway Hydropower Scheme. The power station comprises two turbines with water from the Deuch and Blackwater reservoirs (see separate listings). The penstocks which feed water in are protected from sudden surges of water by the nearby surge tower (see separate listing) The Galloway scheme was a significant technological achievement and the first example of run of the river technology to be successfully utilised on a large scale in Scotland.
The architectural design of Kendoon is a combination of the necessary engineering requirements of a large commercial power station and a finely detailed modernist classical design. The stark roofline and rhythmic articulation of the façade characterise the modern, dynamic attitude with which hydroelectricity was viewed in this period.
The development of the Galloway Hydroelectric Scheme predates the 1943 Hydroelectric (Scotland) Act which formalised the development of Hydroelectricity in Scotland and led to the founding of the North of Scotland Hydroelectric Board. Those schemes which predated the 1943 act were developed by individual companies as a response to particular market and topographic conditions. The completion of a number of schemes (including Galloway, Grampian and those associated with Alcan ' see separate listings) without a national strategic policy framework is groundbreaking as is the consistency of high quality aesthetic and engineering design across all of the schemes.
The Galloway scheme was influential on the future development of hydropower in Scotland. After initial opposition to the parliamentary act granting powers for the completion of the scheme it was approved with a number of safeguards on the landscape and amenity of the area. This necessitated the high quality design of both power stations and dams which characterises the Galloway scheme. This condition also proved influential during the drafting of the Hydroelectric (Scotland) Act of 1943 where the visual impact of future schemes was a primary concern.
Sir Alexander Gibb and Partners was a pioneering engineering company, responsible for a number of high profile works in Scotland, including the Kincardine Bridge (see separate listing). The company was founded by Alexander Gibb in 1921 and quickly became the UK's largest firm of consulting engineers with numerous international clients. Gibb was personally involved in the design and construction of the Galloway scheme, and the pioneering nature of the Galloway development is due, in large part, to his abilities as an engineer. Merz and McLellan were pioneering British electrical engineers and developed a high profile practice, working on a number of power stations across Britain, including Dunstan B, as well as completing hydroelectric work in Italy in the 1980s.
(Listed 2011 as part of Hydroelectric Power Thematic Survey)
External links are from the relevant listing authority and, where applicable, Wikidata. Wikidata IDs may be related buildings as well as this specific building. If you want to add or update a link, you will need to do so by editing the Wikidata entry.
Other nearby listed buildings